......@@ -110,9 +110,9 @@ while data_str != '':
# Verify that sensor values are in valid range
if volt_5v < 4.5 or volt_5v > 5.5 or \
volt_8v < 7 or volt_8v > 9 or \
volt_48v < 45 or volt_48v > 50 or \
volt_48v < 44 or volt_48v > 50 or \
volt_3v3 < 3.0 or volt_3v3 > 4.0 or \
temp_pcb < 10 or temp_pcb > 40:
temp_pcb < 10 or temp_pcb > 50:
tlog.appendLog(11,'Subrack-%s --> SPU I2C sensor values are wrong' % subId[j])