Summary mentions clipped sources when clipAteam = False
I ran LINC target on a Cas A dataset, with both clipAteam=False
and demix=False
, but the summary.log file still mentions a clipped source.
************************************
*** LINC target pipeline summary ***
************************************
Field name: CasA
User-specified baseline filter: [CR]S*&
Additional antennas removed from the data: CS017HBA1, RS503HBA
Selected phase reference antenna: CS004HBA0
CasA
A-Team sources close to the phase reference center: CasA
Of which were demixed: NONE
Of which were clipped: CasA
In the full log I do see that the clipping step is skipped:
^[[1;30mINFO^[[0m [workflow dp3_prep_target] starting step Ateamclipper
^[[1;30mINFO^[[0m [step Ateamclipper] will be skipped
^[[1;30mINFO^[[0m [step Ateamclipper] completed skipped
I don't think anything is clipped, as the flagged data percentage is "only" 25% after prep
. I would have expected that to be much higher if it would have actually clipped, so it seems like some bookkeeping? I've attached my log and input config for reference.