From b40ff5457a2694549c6a5db69c43d2b435d5739a Mon Sep 17 00:00:00 2001
From: Leon Hiemstra <hiemstra@astron.nl>
Date: Thu, 8 Jan 2015 14:26:29 +0000
Subject: [PATCH] already in subdirectories here

---
 .../flash/ip_arria10_asmi_parallel.qsys       | 167 ------------------
 .../flash/ip_arria10_remote_update.qsys       | 118 -------------
 2 files changed, 285 deletions(-)
 delete mode 100644 libraries/technology/ip_arria10/flash/ip_arria10_asmi_parallel.qsys
 delete mode 100644 libraries/technology/ip_arria10/flash/ip_arria10_remote_update.qsys

diff --git a/libraries/technology/ip_arria10/flash/ip_arria10_asmi_parallel.qsys b/libraries/technology/ip_arria10/flash/ip_arria10_asmi_parallel.qsys
deleted file mode 100644
index 0a4e09369d..0000000000
--- a/libraries/technology/ip_arria10/flash/ip_arria10_asmi_parallel.qsys
+++ /dev/null
@@ -1,167 +0,0 @@
-<?xml version="1.0" encoding="UTF-8"?>
-<system name="$${FILENAME}">
- <component
-   name="$${FILENAME}"
-   displayName="$${FILENAME}"
-   version="1.0"
-   description=""
-   tags="INTERNAL_COMPONENT=true"
-   categories="System" />
- <parameter name="bonusData"><![CDATA[bonusData 
-{
-   element $${FILENAME}
-   {
-   }
-   element asmi_parallel_0
-   {
-      datum _sortIndex
-      {
-         value = "0";
-         type = "int";
-      }
-   }
-}
-]]></parameter>
- <parameter name="clockCrossingAdapter" value="HANDSHAKE" />
- <parameter name="device" value="10AX115U3F45I2LG" />
- <parameter name="deviceFamily" value="Arria 10" />
- <parameter name="deviceSpeedGrade" value="2" />
- <parameter name="fabricMode" value="QSYS" />
- <parameter name="generateLegacySim" value="false" />
- <parameter name="generationId" value="0" />
- <parameter name="globalResetBus" value="false" />
- <parameter name="hdlLanguage" value="VERILOG" />
- <parameter name="hideFromIPCatalog" value="true" />
- <parameter name="maxAdditionalLatency" value="1" />
- <parameter name="projectName" value="" />
- <parameter name="sopcBorderPoints" value="false" />
- <parameter name="systemHash" value="0" />
- <parameter name="testBenchDutName" value="" />
- <parameter name="timeStamp" value="0" />
- <parameter name="useTestBenchNamingPattern" value="false" />
- <instanceScript></instanceScript>
- <interface name="clkin" internal="asmi_parallel_0.clkin" type="clock" dir="end">
-  <port name="clkin" internal="clkin" />
- </interface>
- <interface name="read" internal="asmi_parallel_0.read" type="conduit" dir="end">
-  <port name="read" internal="read" />
- </interface>
- <interface name="rden" internal="asmi_parallel_0.rden" type="conduit" dir="end">
-  <port name="rden" internal="rden" />
- </interface>
- <interface name="addr" internal="asmi_parallel_0.addr" type="conduit" dir="end">
-  <port name="addr" internal="addr" />
- </interface>
- <interface name="reset" internal="asmi_parallel_0.reset" type="reset" dir="end">
-  <port name="reset" internal="reset" />
- </interface>
- <interface name="sce" internal="asmi_parallel_0.sce" type="conduit" dir="end">
-  <port name="sce" internal="sce" />
- </interface>
- <interface
-   name="dataout"
-   internal="asmi_parallel_0.dataout"
-   type="conduit"
-   dir="end">
-  <port name="dataout" internal="dataout" />
- </interface>
- <interface name="busy" internal="asmi_parallel_0.busy" type="conduit" dir="end">
-  <port name="busy" internal="busy" />
- </interface>
- <interface
-   name="data_valid"
-   internal="asmi_parallel_0.data_valid"
-   type="conduit"
-   dir="end">
-  <port name="data_valid" internal="data_valid" />
- </interface>
- <interface name="wren" internal="asmi_parallel_0.wren" type="conduit" dir="end">
-  <port name="wren" internal="wren" />
- </interface>
- <interface
-   name="en4b_addr"
-   internal="asmi_parallel_0.en4b_addr"
-   type="conduit"
-   dir="end">
-  <port name="en4b_addr" internal="en4b_addr" />
- </interface>
- <interface
-   name="write"
-   internal="asmi_parallel_0.write"
-   type="conduit"
-   dir="end">
-  <port name="write" internal="write" />
- </interface>
- <interface
-   name="datain"
-   internal="asmi_parallel_0.datain"
-   type="conduit"
-   dir="end">
-  <port name="datain" internal="datain" />
- </interface>
- <interface
-   name="illegal_write"
-   internal="asmi_parallel_0.illegal_write"
-   type="conduit"
-   dir="end">
-  <port name="illegal_write" internal="illegal_write" />
- </interface>
- <interface
-   name="sector_erase"
-   internal="asmi_parallel_0.sector_erase"
-   type="conduit"
-   dir="end">
-  <port name="sector_erase" internal="sector_erase" />
- </interface>
- <interface
-   name="illegal_erase"
-   internal="asmi_parallel_0.illegal_erase"
-   type="conduit"
-   dir="end">
-  <port name="illegal_erase" internal="illegal_erase" />
- </interface>
- <interface name="ex4b_addr" internal="asmi_parallel_0.ex4b_addr" />
- <interface name="die_erase" internal="asmi_parallel_0.die_erase" />
- <interface
-   name="shift_bytes"
-   internal="asmi_parallel_0.shift_bytes"
-   type="conduit"
-   dir="end">
-  <port name="shift_bytes" internal="shift_bytes" />
- </interface>
- <module
-   kind="altera_asmi_parallel"
-   version="14.0"
-   enabled="1"
-   name="asmi_parallel_0"
-   autoexport="1">
-  <parameter name="DEVICE_FAMILY" value="Arria 10" />
-  <parameter name="INTENDED_DEVICE_FAMILY" value="Arria 10" />
-  <parameter name="CBX_AUTO_BLACKBOX" value="ALL" />
-  <parameter name="EPCS_TYPE" value="EPCQL1024" />
-  <parameter name="gui_read_sid" value="false" />
-  <parameter name="gui_read_rdid" value="false" />
-  <parameter name="gui_read_status" value="false" />
-  <parameter name="gui_read_address" value="false" />
-  <parameter name="gui_fast_read" value="false" />
-  <parameter name="DATA_WIDTH" value="QUAD" />
-  <parameter name="gui_read_dummyclk" value="false" />
-  <parameter name="gui_write" value="true" />
-  <parameter name="gui_wren" value="true" />
-  <parameter name="gui_single_write" value="false" />
-  <parameter name="gui_page_write" value="true" />
-  <parameter name="PAGE_SIZE" value="256" />
-  <parameter name="gui_use_eab" value="false" />
-  <parameter name="gui_bulk_erase" value="false" />
-  <parameter name="gui_die_erase" value="false" />
-  <parameter name="gui_sector_erase" value="true" />
-  <parameter name="gui_sector_protect" value="false" />
-  <parameter name="gui_ex4b_addr" value="false" />
-  <parameter name="gui_use_asmiblock" value="false" />
-  <parameter name="WRITE_DUMMY_CLK" value="0" />
-  <parameter name="ENABLE_SIM" value="false" />
- </module>
- <interconnectRequirement for="$system" name="qsys_mm.clockCrossingAdapter" value="HANDSHAKE" />
- <interconnectRequirement for="$system" name="qsys_mm.maxAdditionalLatency" value="1" />
- <interconnectRequirement for="$system" name="qsys_mm.insertDefaultSlave" value="FALSE" />
-</system>
diff --git a/libraries/technology/ip_arria10/flash/ip_arria10_remote_update.qsys b/libraries/technology/ip_arria10/flash/ip_arria10_remote_update.qsys
deleted file mode 100644
index 7178ea0b43..0000000000
--- a/libraries/technology/ip_arria10/flash/ip_arria10_remote_update.qsys
+++ /dev/null
@@ -1,118 +0,0 @@
-<?xml version="1.0" encoding="UTF-8"?>
-<system name="$${FILENAME}">
- <component
-   name="$${FILENAME}"
-   displayName="$${FILENAME}"
-   version="1.0"
-   description=""
-   tags="INTERNAL_COMPONENT=true"
-   categories="" />
- <parameter name="bonusData"><![CDATA[bonusData 
-{
-   element $${FILENAME}
-   {
-   }
-   element remote_update_0
-   {
-      datum _sortIndex
-      {
-         value = "0";
-         type = "int";
-      }
-   }
-}
-]]></parameter>
- <parameter name="clockCrossingAdapter" value="HANDSHAKE" />
- <parameter name="device" value="10AX115U3F45I2LG" />
- <parameter name="deviceFamily" value="Arria 10" />
- <parameter name="deviceSpeedGrade" value="2" />
- <parameter name="fabricMode" value="QSYS" />
- <parameter name="generateLegacySim" value="false" />
- <parameter name="generationId" value="0" />
- <parameter name="globalResetBus" value="false" />
- <parameter name="hdlLanguage" value="VERILOG" />
- <parameter name="hideFromIPCatalog" value="true" />
- <parameter name="maxAdditionalLatency" value="1" />
- <parameter name="projectName" value="" />
- <parameter name="sopcBorderPoints" value="false" />
- <parameter name="systemHash" value="0" />
- <parameter name="testBenchDutName" value="" />
- <parameter name="timeStamp" value="0" />
- <parameter name="useTestBenchNamingPattern" value="false" />
- <instanceScript></instanceScript>
- <interface
-   name="read_param"
-   internal="remote_update_0.read_param"
-   type="conduit"
-   dir="end">
-  <port name="read_param" internal="read_param" />
- </interface>
- <interface
-   name="param"
-   internal="remote_update_0.param"
-   type="conduit"
-   dir="end">
-  <port name="param" internal="param" />
- </interface>
- <interface
-   name="reconfig"
-   internal="remote_update_0.reconfig"
-   type="conduit"
-   dir="end">
-  <port name="reconfig" internal="reconfig" />
- </interface>
- <interface
-   name="reset_timer"
-   internal="remote_update_0.reset_timer"
-   type="conduit"
-   dir="end">
-  <port name="reset_timer" internal="reset_timer" />
- </interface>
- <interface name="clock" internal="remote_update_0.clock" type="clock" dir="end">
-  <port name="clock" internal="clock" />
- </interface>
- <interface name="reset" internal="remote_update_0.reset" type="reset" dir="end">
-  <port name="reset" internal="reset" />
- </interface>
- <interface name="busy" internal="remote_update_0.busy" type="conduit" dir="end">
-  <port name="busy" internal="busy" />
- </interface>
- <interface
-   name="data_out"
-   internal="remote_update_0.data_out"
-   type="conduit"
-   dir="end">
-  <port name="data_out" internal="data_out" />
- </interface>
- <interface
-   name="write_param"
-   internal="remote_update_0.write_param"
-   type="conduit"
-   dir="end">
-  <port name="write_param" internal="write_param" />
- </interface>
- <interface
-   name="data_in"
-   internal="remote_update_0.data_in"
-   type="conduit"
-   dir="end">
-  <port name="data_in" internal="data_in" />
- </interface>
- <module
-   kind="altera_remote_update"
-   version="14.0"
-   enabled="1"
-   name="remote_update_0"
-   autoexport="1">
-  <parameter name="DEVICE_FAMILY" value="Arria 10" />
-  <parameter name="CBX_AUTO_BLACKBOX" value="ALL" />
-  <parameter name="operation_mode" value="REMOTE" />
-  <parameter name="GUI_config_device" value="EPCQ512" />
-  <parameter name="m_support_write_config_check" value="true" />
-  <parameter name="check_app_pof" value="false" />
-  <parameter name="AUTO_CLOCK_CLOCK_RATE" value="0" />
- </module>
- <interconnectRequirement for="$system" name="qsys_mm.clockCrossingAdapter" value="HANDSHAKE" />
- <interconnectRequirement for="$system" name="qsys_mm.maxAdditionalLatency" value="1" />
- <interconnectRequirement for="$system" name="qsys_mm.insertDefaultSlave" value="FALSE" />
-</system>
-- 
GitLab