add wide-band flagging, limit cal outputs

8 jobs for master in 11 minutes and 7 seconds (queued for 2 seconds)
Status Job ID Name Coverage
  Validate Cwl Scripts
passed #105239
validate_scripts

00:06:08

 
  Test Steps
passed #105241
blsmooth

00:03:25

failed #105240
allowed to fail
find_skymodel_cal

00:02:00

 
  Integration Test
failed #105243
faraday_rotation

00:00:24

failed #105246
flag_average

00:01:07

failed #105242
pol_align

00:00:54

failed #105244
prefactor_calibrator

00:00:17

failed #105245
toil

00:01:30

 
Name Stage Failure
failed
toil Integration Test
                                                   `workflows/prefactor_calibrator/prep.cwl#aoflag`
workflows/prefactor_calibrator/prep.cwl:300:5: Field `run` contains undefined reference to
`file:///builds/eosc/prefactor3-cwl/steps/aoflag.cwl`
Running after_script
Running after script...
$ echo "All done"
All done
Cleaning up file based variables
ERROR: Job failed: exit code 1
failed
flag_average Integration Test
{
"msout": null
}
Running after_script
Running after script...
$ echo "All done"
All done
Cleaning up file based variables
ERROR: Job failed: exit code 1
failed
pol_align Integration Test
ERROR [workflow ] Cannot collect workflow output: Workflow contains multiple inbound links to a single parameter but MultipleInputFeatureRequirement is not declared.
INFO [workflow ] completed permanentFail
WARNING Final process status is permanentFail
Running after_script
Running after script...
$ echo "All done"
All done
Cleaning up file based variables
ERROR: Job failed: exit code 1
failed
faraday_rotation Integration Test
ERROR Workflow error, try again with --debug for more information:
Invalid job input record:
subworkflow/faraday_rotation.cwl:13:5: Missing required input parameter 'input_h5parm'

Running after_script
Running after script...
$ echo "All done"
All done
Cleaning up file based variables
ERROR: Job failed: exit code 1
failed
prefactor_calibrator Integration Test
                                                   `workflows/prefactor_calibrator/prep.cwl#aoflag`
workflows/prefactor_calibrator/prep.cwl:300:5: Field `run` contains undefined reference to
`file:///builds/eosc/prefactor3-cwl/steps/aoflag.cwl`

Running after_script
Running after script...
$ echo "All done"
All done
Cleaning up file based variables
ERROR: Job failed: exit code 1
failed
find_skymodel_cal Test Steps
WARNING [job find_skymodel_cal_py] completed permanentFail
{}
WARNING Final process status is permanentFail
Running after_script
Running after script...
$ echo "All done"
All done
Cleaning up file based variables
ERROR: Job failed: exit code 1