Issue when apply solutions during solve with uv selection
Created by: aroffringa
Arianna found that a gaincal with a uvlambdamin
and applysolutions=true
causes all baselines that are filtered by the uvlambdamin
to be flagged. This is confusing, and inconsistent with how a separate applycal step works, as that step would just apply the solutions on those filtered baselines and keep them unflagged (if they are unflagged and the involved antennas succeed in calibration of course).
So it would be better if applysolutions=true would apply the solutions on filtered baselines too.
msin=ACE_SB371_2min-3ch1s_LST23h30_08.MS
msin.datacolumn=DATA
msout=
msout.datacolumn=CORRECTED_MODEL_DATA
steps=[gaincal]
gaincal.parmdb=instrumentDI.parmdb
gaincal.caltype=fulljones
gaincal.solint=12
gaincal.nchan=0
gaincal.usebeammodel=false
gaincal.usemodelcolumn=true
gaincal.uvlambdamin=20
gaincal.applysolution=true